DL-CRN50299 Adapter for measuring valve stroke and excess stroke of CRIN 2/3 injectors
Обзор
DL-CRN50299 Adapter for measuring the valve stroke (AH) of CRIN 2 / CRIN 3 injectors with detachable and non-detachable armature, as well as for measuring excess stroke.
Brief description of measurements:
Reset the readings of the indicator
Calibrate indicator
Join Dimension Constituents
Take measurements, repeat 3 times
Indicator is not included in delivery.
The Instruction Steps tab describes the sequence of measurements. Full instructions are included with the adapter.
To measure and subsequently repair injectors, you will need a set of original washers, which is purchased separately by the client. By selecting the washer or grinding it, the required stroke is achieved. Work on grinding and adjustment is conveniently performed on a GM-08 surface grinder with a lower movable work table.
CONTENTS OF DELIVERY:
Adapter case DL-CR31555 — 1 pc.
Adapter nut DL-CR31527 — 1 pc
Measuring probe DL-CRN30708 — 1 pc.
Anchor fixing sleeve DL-CR31556 — 1 pc.
INSTRUCTION STEPS:
1. Valve stroke measurement
1.1. Measurement of valve stroke with non-separable anchor
1.2. Measurement of the valve travel with a collapsible anchor
2. Overtravel measurement
2.1. Necessary equipment for measurement
2.2. Measurement of the excess travel of a collapsible anchor:
To improve accuracy, measure 3 times.
Attention! Full measurement instructions are included with the kit.