Валюта: Р $

Корзина: пусто

ОБЩАЯ СУММА (с учетом скидки)пусто

Перейти в корзину

SPF-1108M Assay test bench for testing high-pressure fuel pumps (11kW)

Article: no article
В наличии
0 Р
Количество:
  • Overview
  • Schemes

Обзор

SPF-1108
Assay test bench for testing high-pressure fuel pumps

POWER OF THE BASIC DRIVE 11kW

MEASURING UNIT OF 8 MEASURING FLASKS

The bench is intended for testing and adjusting the devices of the power system of diesel engines during their repairs and maintenance.

TESTING TYPES

The assay test bench allows the following types of tests and adjustments:

  • determination of the volume of fuel injection doses for different shaft speeds of the high-pressure fuel pump, corresponding to:
  • - engine start (starting dose),

    - idling (dose of idling),

    - the beginning and end of the positive and negative adjustment,

    - engine rated power (nominal, so-called measuring dose), as well as revolutions, defining the so-called high-speed characteristic of a high-pressure fuel pump;

  • determining the speed of rotation of the start and end of the fuel injection shutdown by the rotation speed regulator (maximum idling speed), defining the so-called adjustable speed range;
  • geometric start of compression (adjustment of the preliminary stroke), as well as angular gaps between sections of the high-pressure fuel pump;
  • scatter (non-uniformity) of doses of fuel injected by different sections of the high-pressure fuel pump, which should not exceed 2% of the nominal dose;
  • operation of the electromagnetic shut-off valve;
  • checking the suction discharge of the feed pumps;
  • checking the injection pressure of the feed pumps;
  • checking the performance of feed pumps;
  • check of tightness and permeability of the fuel filter.

  • TECHNICAL DETAILS

  • rotational speed: 30 - 3500 min-1
  • direction of rotation - left / right
  • power two-la (nom.) -11kW
  • Torque 1050 - 3000 min-1: 68.2 - 24.2 Nm
  • programmable number of injections (every 50): 50 - 1000
  • tank capacity: approximately 30 dm3
  • number of measuring sections -8
  • measuring flasks capacity: 44 and 260 +/- 0.25 cm3
  • power supply: 3x400V / 230V ~ 50Hz
  • maximum amperage: -29A
  • heater power test fluid - 1000W


  • Schemes


    Дорогие друзья!

    К сожалению, Ваш браузер не поддерживает современные технологии используемые на нашем сайте.

    Пожалуйста, обновите браузер, скачав его по ссылкам ниже, или обратитесь к системному администратору, обслуживающему Ваш компьютер.

    Internet Explorer

    Microsoft

    Chrome

    Google

    Safari

    Apple

    Opera

    Opera Software

    Firefox

    Mozilla

    Вверх